DE-5203 Мультиметр цифровой
Resistance, Continuity, Diode, Capacitance, Frequency, Duty, Temperature, REL.
True RMS
22000 counts
- LCD Display:22000 Counts (main) & bar graph 46 segments
- Sampling Rate:Approx. 2 times per second
- Range:Automatic & manual
- Overload:”OL” Display On LCD
-
Low Battery:
Display on LCD
- Auto Power Off:In 15 Minutes Approx.
- Battery:AA 1.5V x2
- Safety standard:IEC 61010-1 CAT III 600V ,CAT.II 1000V
Measurement Ranges:
23°C ± 5°C max. 80%R.H. Accuracy: ±(%rdg +dgt)
Measurement |
Range |
Resolution |
Accuracy (Responding Hz) |
Input Impedance |
Max. Input Voltage |
|
DE-5200(sine wave) |
DE-5202 / 5203 |
|||||
ACV |
2.2000V |
0.0001V |
0.7%+15(40Hz~1kHz) |
*0.7%+40(40Hz~1kHz) |
Approx. 11MΩ |
1000V rms |
22.000V |
0.001V |
0.7%+10(40Hz~1kHz) |
*0.8%+40 (40Hz~1kHz) *1.5%+40(1kHz~5kHz) |
Approx. 10MΩ |
||
220.00V |
0.01V |
|||||
1000.0V |
0.1V |
1.0%+10(40Hz~1kHz) |
*1.0%+40(40Hz~2kHz) |
*True RMS value: applicable to 10%~100% of the range
Measurement |
Range |
Resolution |
Accuracy |
Input Impedance |
Max. Input Voltage |
DCV |
2.2000V |
0.0001V |
0.1%+5 |
Approx. 11MΩ |
1000V rms |
22.000V |
0.001V |
Approx. 10MΩ |
|||
220.00V |
0.01V |
||||
1000.0V |
0.1V |
0.3%+5 |
Measurement |
Range |
Resolution |
Accuracy |
Input Impedance |
Max. Input Voltage |
DCmV |
220.00mV |
0.01mV |
0.1%+5 |
≧100MΩ |
1000V rms |
Measurement |
Range |
Resolution |
Accuracy (Responding Hz) |
Input Impedance |
Max. Input Voltage |
|
DE-5200(sine wave) |
DE-5202 / 5203 |
|||||
ACmV |
220.00mV |
0.01mV |
0.5%+15(40Hz~1kHz) 1.2%+20(1Hz~2kHz) |
*0.5%+30(40Hz~1kHz) *1.2%+30(1Hz~10kHz) |
≧100MΩ |
1000V rms |
*True RMS value: applicable to 10%~100% of the range
Measurement |
Range |
Resolution |
Accuracy |
Overload Protection |
Ω Resistance |
220.00 Ω |
0.01Ω |
0.5%+5 |
1000V rms |
2.2000kΩ |
0.0001kΩ |
|||
22.000kΩ |
0.001kΩ |
|||
220.00kΩ |
0.01kΩ |
|||
2.2000MΩ |
0.0001MΩ |
|||
22.000MΩ |
0.001MΩ |
1.0%+10 |
||
220.0MΩ |
0.1MΩ |
5.0%+10 |
Measurement |
Range |
Resolution |
Remarks |
Open-loop Voltage |
Overload Protection |
Continuity |
220.00Ω |
0.01Ω |
Buzzer emits at around ≦30Ω |
-3.0V |
1000V rms |
Measurement |
Range |
Resolution |
Accuracy |
Open-loop Voltage |
Overload Protection |
Diode |
2.2000V |
0.0001V |
0.5%+5 |
>2.5V |
1000V rms |
Measurement |
Range |
Resolution |
Accuracy |
Open-loop Voltage |
Overload Protection |
Capacitance |
22.000nF |
0.001nF |
1.5%+20 |
At 22nF/220nF ranges Press “REL” to offset the reading before measurement |
1000V rms |
220.00nF |
0.01nF |
||||
2.2000μF |
0.0001μF |
2.0%+20 |
|||
22.000μF |
0.001μF |
||||
220.00μF |
0.01μF |
||||
2.2000mF |
0.0001mF |
2.0%+20 |
|||
22.000mF |
0.001mF |
||||
220.00mF |
0.01mF |
6.0%+20 |
Measurement |
Range |
Resolution |
Accuracy |
Remarks |
Overload Protection |
Hz & Duty*** |
22.00Hz* |
0.01Hz |
0.1%+5 |
* valid>2.00Hz ** valid > 20.0Hz ***Duty:5%~94.9% (<10kHz3Vp-p) resolution: 0.1%. Display: UL(<5.0%) OL (>94.9%) |
1000V rms |
220.0Hz** |
0.1Hz |
||||
22.000kHz |
0.001kHz |
||||
220.00kHz |
0.01kHz |
Measurement |
Range |
Resolution |
Accuracy (Responding Hz) |
Overload Protection |
||
DE-5200(sine wave) |
*DE-5202 / 5203 |
250mA/ 1000V fuse |
||||
AC |
μA |
220.00μA |
0.01μA |
0.8%+10(40Hz~1kHz) 1.5%+10(1kHz~2kHz) |
*0.8%+30(40Hz~1kHz) *1.5%+30(1kHz~10kHz) |
|
2200.0μA |
0.1μA |
|||||
mA |
22.000mA |
0.001mA |
||||
220.00mA |
0.01mA |
|||||
**A |
**10.000A |
0.001A |
1.8%+20(40Hz~1kHz) 2.0%+20(1kHz~2kHz) |
*1.5%+30(40Hz~1kHz) *2.0%+40(1kHz~10kHz) |
10A/1000V fuse |
*True RMS value: applicable to 10% to 100% of the range.
**over range 11 ~ 20A stands with 30 sec. max.
Measurement |
Range |
Resolution |
Accuracy |
Overload Protection |
|
DC |
μA |
220.00μA |
0.01μA |
0.5%+5 |
250mA/ 1000V fuse |
2200.0μA |
0.1μA |
||||
mA |
22.000mA |
0.001mA |
|||
220.00mA |
0.01mA |
0.8%+5 |
|||
A |
*10.000A |
0.001A |
1.2%+10 |
10A/1000V fuse |
over range 11 ~ 20A stands with 30 sec. max.
Measurement |
Range |
Resolution |
Accuracy |
||
DE-5200/5202 |
DE-5203 |
||||
°C °F |
-40.0℃~ 1000.0℃ -40.0℉~ 1830.0℉ |
0.1℃ 0.1℉ |
|
-40.0℃ ~ 400.0℃ |
1.0% +4℃ |
-40.0℉ ~ 752.0℉ |
1.0% +8℉ |
||||
400.1℃ ~ 1000.0℃ |
1.5% +10℃ |
||||
752.1℉ ~ 1830.0℉ |
1.5% +18℉ |
Measurement |
Range |
Accuracy |
Remarks |
Peak Hold* |
DCV, ACV |
3.0%+50 |
* pulse width≧100uS
valid≧2000 counts |
DCmV, ACmV |
|||
DCμA, ACμA |
|||
ACmA, DCmA |
|||
DCA, ACA |
Temperature coefficient: 0.1 x (specified accuracy) / ℃ (<18℃ or >28℃)
TEMP./Humidity:
- Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
- Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)
Dimension & Weight:
- 181(L)x91(W)x57(H)mm
- Approx.400g (Excluding battery)
Accessories:
- Battery AA 1.5V x 2
- Instruction Manual x 1
- Test Lead (red + black) x 1
-
True RMS
- Bar Graph
- Peak-max. & Peak-min Hold
- Max./Min Hold
- Data Hold
- Delay Hold
-
Backlight
- Auto Range & Manual Range
- Auto Power Off Selection
- Relative Check
- AC 3dB Bandwidth LPF
- HCF Signal Detection
- Temperature Measurement